Blast-Resistant Tubular Frame Door of Class EXR 4 according to DIN EN 13123-2

The robust tubular frame door from the SOMMER FU series is made of thermally insulated steel, offering blast resistance and meeting Class EXR 4 requirements as per DIN EN 13123-2. With dimensions of 2372 x 2222 mm and a weight of 2000 kg, it ensures outstanding stability and safety.

 

read more

 

Technical Parameters

Discover the peak performance: A quick overview of the technical specifications of our tubular frame door!

  • Reflected Pressure: 1685 kPa
  • Impulse: 982 kPa-ms
  • Compliance: Class EXR 4 according to DIN EN 13123-2
  • Compatible with Burglary and Bullet Resistance:
  • Bullet Resistance as per DIN EN 1522: Standard FB4 NS; optional FB6 NS and FB7 NS
  • Burglary Resistance as per DIN EN 1627: Standard RC4; optional RC5